V2008

FUNCTIONS

* digit countdown/up timer;

*It can directiy drive LCD; 

*Maximum countdown time is 99:59 Minutes; 

*Bonding option is for alarm time 32 or 64 seconds;

*Bonding option is for up/down or just down function.

FEATURES

*Internal voltage doubler;

*32,768Hz quartz crystal time base; 

*Minutes and Seconds set independently;

*Direct drive buzzer; 

*Low power dissipation; 

*Protection against static discharge. 

ELECTRICAL CHARACTERISTICS


Characteristics

Sym

Min

Typ

Max

Unit

REMARKS

Operating Voltage

Vdd

1.2

1.5

2

V

-

Quiescent Current

Isb

-

1

2

µA

No Load

Operating Current

Iop

-

-

9

µA

-

Input high voltage

Vih

Vdd-0.3

-

Vdd

V

-

Input low voltage

Vil

Vss

-

Vss+0.3

V

-

Switch activation current

Isw

-

-

3

µA

Vin=Vdd

Alarm drive cuurrent

Iala

0.5

2

-

mA

Vala=0.5V

Oscillator input Frequency

Fosc

-

32768

-

Hz

±30%Tol

LCD frequency

Flcd

-

32

-

Hz

-

Time stability

Tstb

-

1

-

ppm

Vdd=3V


Bonding option:

1.jpg

FUNCTION DESCRIPTION

The timing mode:

* add electric LCD display is prefer;

* SSET, MSET key set time, time setting in the initial model and only effective

counter to stop or reset condition. Independently with press the two key points,

the second set, the colon shows but not flashing;

* press the SSET with MSET button at the same time, the counter is reset to 00:00;

Timing starts * time setting and trigger the START button, the colon START flashing.

* in the process of the timer, press any key to stop time, press the MSET key or SSET key at this time,

the current time is preset time, the colon shows but not flashing at this time.

Counter in time setting state, trigger START key timing starts time setting state.

* the end of the timing, LCD display for 00:00 and colon but not flashing, the rings at beginning

(rings at 32 seconds or 64 seconds long);

* the end of the timing, and rings at the end, the LCD display the preset time.

(if is to press the START key rings at stop, LCD display preset time;

If it is according to the SSET or MSET key rings at stop, LCD display to 00:00,

then press the START button LCD display preset time.)

Is the timing mode:

* is timing mode only when reset or power up haven't set a time effectively,

to trigger the START button and START the time.

* time is after the start timing cycle timing to 99;

* is in the process of the timing, press any key to stop time,

at this time to trigger the START time key to continue;

* is timing mode, press any key to stop, then press MSET and SSET set the timing time,

timer transform to the timing mode.

LCD field distribution


SEG8

SEG7

SEG6

SEG5

SEG4

SEG3

SEG2

SEG1

COM1

A1

B1

A2

B2

A3

B3

A4

B4

COM2

F1

G1

F2

G2

F3

G3

F4

G4

COM3

E1

C1

E2

C2

E3

C3

E4

C4

COM4


D1


D2

COLON

D3


D4

glyph LCD display

2.jpg

APPLICATION INFORMATION

Pad

Name             

X

Y

Pad

Name

X

Y

1

COM1             

69.5

66.5

15

OSCO

1229.5

366

2

GND

69.5

215.4

16

OSCI

1229.5

261

3

OPT3

69.5

320.4

17

COM3

1229.5

66.5

4

CAP2

69.5

425.4

18

COM4

1122

66.5

5

CAP1

69.5

681.4

19

S8

1017

66.5

6

Sset

384.2

793.5

20

S7

912

66.5

7

Mset

489.2

793.5

21

S6

807

66.5

8

START               

594.2

793.5

22

S5

702

66.5

9

OPT1

699.2

793.5

23

S4

597

66.5

10

VDD

804.2

793.5

24

S3

492

66.5

11

BZ

1229.5

791.5

25

S2

387

66.5

12

BZB

1229.5

681

26

S1

282

66.5

13

VSS

1229.5

576

27

COM2

177

66.5

14

OPT2

1229.5

471

28




APPLICATION DIAGRAM

3.jpg

* chip left corner as the origin, the X and Y coordinates for PAD center;

* VDD chip substrate.


上一篇:没有了! 下一篇:The countdown to 99 hours of 99 points